Industrial Fixed Gas Detection for UK Manufacturing

DSEAR & COSHH aware

We design, install and maintain reliable fixed gas detection systems — ATEXrated where required — to protect people, assets and continuity of production.

Why gas detection matters

Unplanned gas releases cause injury, ill health, fires, explosions and production downtime. UK employers have legal duties under DSEAR (Dangerous Substances and Explosive Atmospheres) and COSHH to manage risks from hazardous gases.
An engineered gas detection system forms part of a layered defence: identify, detect, alarm, isolate and evacuate.

Industrial Fixed Gas Detection for UK Manufacturing
Fixed Gas Detection Products for UK Industries

Our approach

Survey, design, deliver, support

Site survey & hazard mapping

Identify fugitive emission points, process vents, confined spaces and likely release directions.

Specification & zoning

Select sensor types and certify equipment to match DSEAR/ATEX zones and COSHH requirements.

Installation & integration

Fixed detectors, control panels, BMS/SCADA integration and alarm management.

Commissioning & verification

Calibration, functional tests and documented acceptance tests.

Maintenance & training

Scheduled calibration, sensor replacement, alarms testing and operator training.

Types of sensors & when to use them

Sensor placement & coverage - practical guidance

Regulatory snapshot (UK)

DSEAR — requires risk-based controls for explosive atmospheres.
COSHH — requires monitoring and control of hazardous exposures where applicable.
ATEX/IECEx — equipment certification for hazardous zones.

Employers must assess, document and implement measures including gas detection where appropriate.

Quality & standards

Systems are designed to recognised standards and best practice: BS/EN guidance for gas detectors and control panels, site-specific acceptance tests and documented maintenance regimes.

Key services

Maintenance, calibration & lifecycle

A gas detector is only useful if it works when you need it.
Implement a written maintenance plan covering periodic calibration (or bump tests), sensor replacement, alarm checks and record-keeping.
Maintain traceable calibration certificates and keep a log of alarm events and corrective actions.

Recommended checks:

  • Bump test before use (portable) or weekly checks for fixed systems depending on risk.
  • Full calibration at manufacturer-recommended intervals, or when readings drift.
  • Battery and communications checks for wireless devices.
  • Functional testing of alarm outputs, relays and integration with shutdown systems.

Typical system architecture

From field sensors to control and action: sensors junction boxes control panel / PLC / safety system operator HMI & alarms SCADA/BMS logging.
Modern systems offer data logging, remote telemetry and secure cloud-based dashboards for compliance reporting and trend analysis.

Example features:

  • Multi-channel control panels with redundant relays
  • Event logging and time-stamped alarm histories
  • Remote telemetry (4–20mA, Modbus, BACnet, IoT gateways)
  • Operator access levels and audit trails

FAQs

Not always — you must perform a risk assessment. For continuous processes with significant gas inventory or explosion risk, fixed detectors are usually required.

Follow manufacturer guidance and the site risk assessment — typical intervals are 3–12 months. Perform bump tests more frequently.

Yes — common protocols include Modbus, 4–20mA and BACnet. Ensure cybersecurity and fail-safe behaviour are considered in the design.